1.2. Slide expediter toward pipe and secure
using two (2) circumferential bands of
19mm (3/4”) wide tape.
1.3. Place UL
®
label provided as shown,
locate on opposite side from rectangular
side opening.
Pipe Heating Cable 134N
HSX
®
or FLX Heating Cable System
Install Cable per NEC Article 427
Thermon Manufacturing Co.
100 Thermon Dr., San Marcos, Texas 78666
1-800-730-4328 PN 27400
1.4. Cutandremoveheatingcableoverjacket.
Do not cut bus metallic braid.
1.5. Separatebraidstrandsatedgeofoverjacket
and pull cable through opening.
1.6. Twist braid into a pigtail. Trim ends of braid.
1.1b. Two cables.
152mm
(6”)
Braid
Power connection for FLX -OJ cables and HSX cables. For cables with braid only, skip to Step 3.1 on page 4.
Tape Provided Separately
UL Label
1.1a. For one, two or three cables. Insert cable
into expediter, grommet.
PCS-COM In-line and T-Splice Kit
1.1c. Three cables.