Thermon ZE-B Beacon Terminator Manual de usuario Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 4
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
Locked
Position
13. To remove cap, de-energize circuit, lift latch
mechanism, and unscrew cap.
12. Engage threads. Rotate light module cover
clockwise and tighten cap securely. Make sure
latch mechanism is in the locked position.
11. Arrange crimped leads to fi t inside light mod-
ule base. Slide the light module cover over
light module.
Light Module
Cover
Lens
Expediter
Assembly
Light Module
Unlocked
Position
9. Snap on crimp insulators.
Light Module
Expediter
Assembly
Crimp
Insulators
10. Slide silicone caps over crimp insulators.
Install Light Module to Expediter.
Silicone Cap
Terminator
TM
ZE-B Beacon INSTALLATION PROCEDURES
Specifi cations and information subject to change without notice.
PN50844U-1110
THERMON . . . The Heat Tracing Specialists
®
www.thermon.com
Corporate Headquarters
100 Thermon Dr.
PO Box 609
San Marcos, TX 78667-0609
USA
Phone: +1 512-396-5801
European Headquarters
Boezemweg 25
PO Box 205
2640 AE Pijnacker
The Netherlands
Phone: +31 (0) 15-36 15 370
For the Thermon offi ce nearest you
visit us at . . .
www.thermon.com
Vista de pagina 3
1 2 3 4

Comentarios a estos manuales

Sin comentarios